Detailed Selling Lead Description
Brand: telebahn
Model: 620_005
BS LSA C48L
Main Features:
◎ High nominal current
◎ For installing at LPZ 0B-2 or higher boundary
Application:
According to GB 18802.21-20004/IEC 61643-21, based on the LSA-PLUS wiring technology, easy for installation. It can provide surge voltage protection for one pair of conductors or two single conductors. Mainly used for telephone system and also measurement and control fields.
Specifications:
Technical data
Nominal voltage
UN
48V
Rated voltage
(max. continuous voltage)
Uc
80V-/56.4V~
Nominal current
IL
360mA
Nominal discharge
current(8/20) per line
In
5kA
Voltage protection level
at 1kV/ ms
Up
≤160V(line/PG)
Series impedance per line
R
100mH + 1.7W
Bandwidth
fG
140KHz(line/PG)
Parasitic capacitance
C
≤0.4nF(line/PG)
Response time
tA
≤20ns(line/line)
≤20ns(line/PG)
Operating
temperature range
-20℃…+80℃
Pluggable into
LSA-PLUS disconnection block
Earthing via
earthing busbar
Enclosure material
orange thermoplastic, UL94-V0
Test standards
GB 18802.21-2004; IEC 61643-21:2000
Certification
CE